अनुसंधान और परीक्षण सुविधाएं
facilities View
Total number of Record(s): 88
Name of the Facility | Institute | Area | Type of facility | Type of measurement/ Analysis Available |
---|---|---|---|---|
Liquid Nitrogen Plant | Punjab University, Chandigarh | रसायन विज्ञान | Research | Liquid nitrogen for R&D work, Cryo magnets, Medical Labs./Hospitals, Detectors, Material Characterisation, etc. |
FT-IR Spectrometer | Punjab University, Chandigarh | भौतिक विज्ञान | Research | Measurement in the region including IR spectra of liquids (in KBr cell), solids (in KBr pellets). |
UV-VIS-NIR Spectrometer | Punjab University, Chandigarh | भौतिक विज्ञान | Research | Usual measurement/studies in the region. |
Elemental Analyser | Punjab University, Chandigarh | रसायन विज्ञान | Testing | Estimation of carbon, hydrogen and nitrogen in the samples. |
LC-MS/MS | Punjab University, Chandigarh | भौतिक विज्ञान | Research | Nominal Mass studies, Accurate mass studies, Fragmentation studies through MS/MS and LC-MS studies |
FT-NMR Spectrometer | Punjab University, Chandigarh | भौतिक विज्ञान | Research | 1D Spectra-normal for 1H, 13C, 31P, 119Sn, 27Al, 23Na, 11B, 59Co; Homo-nuclear decoupling (proton); Hetro-nuclear gated decoupling; Hetro-nuclear inverse decoupling; NOE experiments; 2D spectroscopy with gradients (COSY, NOESY, HMQC, HMBC, OESY, TOCSY, C-H correlation experiments); Editing spectroscopy-DEPT 45, DEPT 90, DEPT135; Gated and inverse gated decoupling experiments; 1H water suppression; Variable temperature studies. |
X-ray Fluorescence Spectrometer (WD-XRF) | Punjab University, Chandigarh | भौतिक विज्ञान | Research | Qualitative, quantitative analysis using standards and semi-quantitative analysis using standardless software; Accurate elemental analysis from Carbon to Uranium in materials, including trace elements; Samples in solid, pressed powder and liquid form can be analyzed. |
X-ray Diffractometer (powder) | Punjab University, Chandigarh | भौतिक विज्ञान | Research | 2? vs intensity plots/diffractograms; Phase identification through search/match method, particle size and strain determination by Scherer method, The results are given in the form of intensity verses 2-theta position with printed peak position, d-values, FWHM and relative intensity |
Transmission Electron Microscope | Punjab University, Chandigarh | जीवन विज्ञान | Research | Internal structure of any thin section, film, replica or particulate material |
Scanning Electron Microscope | Punjab University, Chandigarh | जीवन विज्ञान | Research | Surface topographic/morphological studies of microstructures on bulk specimens of biological/other materials; Micrographs on 35 mm film; SEI, BEI images; Image analysis. |