Testing
Thermal Analysis System (TG/DTA)
Area:
Make Model:
Perkin Elmer Diamond TG/DTA
Type of measurement/ Analysis Available:
All types of thermal analysis studies/testing
Application:
NA
Major Specifications/ Accessories available:
TG Sensitivity : 200 mg DTA Sensitivity: +1000µV Temperature range: Ambient to 1200º C
Type of facility:
Institute:
Sophisticated Test and Instrumentation Centre, Kochi
Thermal Analysis System (DSC)
Area:
Make Model:
Mettler Toledo DSC 822e
Type of measurement/ Analysis Available:
DSC thermograms of solid samples
Application:
NA
Major Specifications/ Accessories available:
Temperature range:-150º C to 700º CTemp. Accuracy: + 0.2 0 C
Type of facility:
Institute:
Sophisticated Test and Instrumentation Centre, Kochi
DTA
Area:
Make Model:
AIMIL 1600 DTA
Type of measurement/ Analysis Available:
Thermal analysis studies/testing including melting points, crystallization behavior, glass transition, phase transition, thermal stability etc.
Application:
NA
Major Specifications/ Accessories available:
Temp. range: 400º C to 1600º C
Type of facility:
Institute:
Nagpur University
TGA/SDTA
Area:
Make Model:
Mettler Tolledo
Type of measurement/ Analysis Available:
Thermal analysis studies/testing including melting points, crystallization behavior, glass transition, phase transition, thermal stability etc.
Application:
NA
Major Specifications/ Accessories available:
Temp. range: Ambient to 1000º C
Type of facility:
Institute:
Nagpur University
DSC
Area:
Make Model:
Mettler DSC 30S
Type of measurement/ Analysis Available:
Thermal Analysis Studies/Testing Including Melting Points, Crystallization Behavior, Glass Transition, Phase Transition, Thermal Stability Etc.
Application:
NA
Major Specifications/ Accessories available:
Temp. range: -150º C to 600º C
Type of facility:
Institute:
Nagpur University
Transmission Electron Microscope
Area:
Make Model:
Jeol 1200 EX II
Type of measurement/ Analysis Available:
Study of ultrastructures of materials; Photomicrographs of ultrathin sections of biological samples.
Application:
NA
Major Specifications/ Accessories available:
Resolution: upto 4.5 0A Acc. voltage: upto 120 kV
Magnification: upto 10,00,000 xUltramicrotome
Glass/diamond knife maker
Type of facility:
Institute:
Nagpur University
Transmission Electron Microscope
Area:
Make Model:
Jeol JSM 100 CX II
Type of measurement/ Analysis Available:
Study of ultra-structures of biological samples; Characterization of nano particles, determination of crystal shape, angles and orientation, crystal- defect, electron diffraction studies etc. Normal TEM image/micrographs on plate film.
Application:
NA
Major Specifications/ Accessories available:
Magnification: upto 4,50,000
Resolution: 3
Ultramicrotome
Type of facility:
Institute:
North-Eastern Hill University, Shillong
Universal Testing Machine
Area:
Make Model:
Simadzu AG 100 KNG
Type of measurement/ Analysis Available:
Bending, compression, Tensile & Inter laminar shear testing of materials.
Application:
NA
Major Specifications/ Accessories available:
Range: 1 kgf to 10,000 kgf load cells
Type of facility:
Institute:
Sophisticated Instrumentation Centre for Applied Research and Testing - SICART, Vallabh Vidyanagar
Graphite Furnace (transversely heated)
Area:
Make Model:
Analytik Jena Vario 6
Type of measurement/ Analysis Available:
Direct analysis of solid samples with better detection limits.
Application:
NA
Major Specifications/ Accessories available:
Range: 190 to 870 nm Detection limit: ppb.
Type of facility:
Institute:
North-Eastern Hill University, Shillong
Atomic Absorption Spectrometer
Area:
Make Model:
Perkin Elmer 3110
Type of measurement/ Analysis Available:
Trace element analysis of elements in rock/ore, oil plants, biological samples, water etc.
Application:
NA
Major Specifications/ Accessories available:
Range: 193.7 to 780 nm Detection limit: ppm.
Type of facility:
Institute:
North-Eastern Hill University, Shillong