Testing

Testing

Thermal Analysis System (TG/DTA)

Make Model: 
Perkin Elmer Diamond TG/DTA
Type of measurement/ Analysis Available: 
All types of thermal analysis studies/testing
Application: 
NA
Major Specifications/ Accessories available: 
TG Sensitivity : 200 mg DTA Sensitivity: +1000µV Temperature range: Ambient to 1200º C
Type of facility: 
Institute: 
Sophisticated Test and Instrumentation Centre, Kochi
Meta Tagging: 
STIC, Thermal analysis

Thermal Analysis System (DSC)

Make Model: 
Mettler Toledo DSC 822e
Type of measurement/ Analysis Available: 
DSC thermograms of solid samples
Application: 
NA
Major Specifications/ Accessories available: 
Temperature range:-150º C to 700º CTemp. Accuracy: + 0.2 0 C
Type of facility: 
Institute: 
Sophisticated Test and Instrumentation Centre, Kochi
Meta Tagging: 
STIC, Thermal analysis, Thermograms

DTA

Make Model: 
AIMIL 1600 DTA
Type of measurement/ Analysis Available: 
Thermal analysis studies/testing including melting points, crystallization behavior, glass transition, phase transition, thermal stability etc.
Application: 
NA
Major Specifications/ Accessories available: 
Temp. range: 400º C to 1600º C
Type of facility: 
Institute: 
Nagpur University
Meta Tagging: 
Nagpur University, Thermal analysis

TGA/SDTA

Make Model: 
Mettler Tolledo
Type of measurement/ Analysis Available: 
Thermal analysis studies/testing including melting points, crystallization behavior, glass transition, phase transition, thermal stability etc.
Application: 
NA
Major Specifications/ Accessories available: 
Temp. range: Ambient to 1000º C
Type of facility: 
Institute: 
Nagpur University
Meta Tagging: 
Nagpur University, Thermal analysis

DSC

Make Model: 
Mettler DSC 30S
Type of measurement/ Analysis Available: 
Thermal Analysis Studies/Testing Including Melting Points, Crystallization Behavior, Glass Transition, Phase Transition, Thermal Stability Etc.
Application: 
NA
Major Specifications/ Accessories available: 
Temp. range: -150º C to 600º C
Type of facility: 
Institute: 
Nagpur University
Meta Tagging: 
Nagpur University, Thermal analysis

Transmission Electron Microscope

Make Model: 
Jeol 1200 EX II
Type of measurement/ Analysis Available: 
Study of ultrastructures of materials; Photomicrographs of ultrathin sections of biological samples.
Application: 
NA
Major Specifications/ Accessories available: 
Resolution: upto 4.5 0A Acc. voltage: upto 120 kV
Magnification: upto 10,00,000 xUltramicrotome
Glass/diamond knife maker
Type of facility: 
Institute: 
Nagpur University
Meta Tagging: 
Nagpur University, Electron Microscope, Photomicrographs, biological samples

Transmission Electron Microscope

Make Model: 
Jeol JSM 100 CX II
Type of measurement/ Analysis Available: 
Study of ultra-structures of biological samples; Characterization of nano particles, determination of crystal shape, angles and orientation, crystal- defect, electron diffraction studies etc. Normal TEM image/micrographs on plate film.
Application: 
NA
Major Specifications/ Accessories available: 
Magnification: upto 4,50,000
Resolution: 3
Ultramicrotome
Type of facility: 
Institute: 
North-Eastern Hill University, Shillong
Meta Tagging: 
NEHU, Transmission electron microscope, biological samples, nano particles

Universal Testing Machine

Make Model: 
Simadzu AG 100 KNG
Type of measurement/ Analysis Available: 
Bending, compression, Tensile & Inter laminar shear testing of materials.
Application: 
NA
Major Specifications/ Accessories available: 
Range: 1 kgf to 10,000 kgf load cells
Type of facility: 
Institute: 
Sophisticated Instrumentation Centre for Applied Research and Testing - SICART, Vallabh Vidyanagar
Meta Tagging: 
SICART, Bending, Compression, Tensil, materials

Graphite Furnace (transversely heated)

Make Model: 
Analytik Jena Vario 6
Type of measurement/ Analysis Available: 
Direct analysis of solid samples with better detection limits.
Application: 
NA
Major Specifications/ Accessories available: 
Range: 190 to 870 nm Detection limit: ppb.
Type of facility: 
Institute: 
North-Eastern Hill University, Shillong
Meta Tagging: 
NEHU, Graphite Furnace, solid samples

Atomic Absorption Spectrometer

Make Model: 
Perkin Elmer 3110
Type of measurement/ Analysis Available: 
Trace element analysis of elements in rock/ore, oil plants, biological samples, water etc.
Application: 
NA
Major Specifications/ Accessories available: 
Range: 193.7 to 780 nm Detection limit: ppm.
Type of facility: 
Institute: 
North-Eastern Hill University, Shillong
Meta Tagging: 
NEHU, Atomic absoption spectrometer, biological samples

Pages