Physical Sciences

Physical Sciences

GC-Mass Spectrometer

Make Model: 
Varian 1200L
Type of measurement/ Analysis Available: 
Separation/identification of organic compounds
Application: 
NA
Major Specifications/ Accessories available: 
Single quadrapole, EI Mass range: 10-800 amu Resolution: 1 amu NIST library
Type of facility: 
Institute: 
Sophisticated Test and Instrumentation Centre, Kochi
Meta Tagging: 
STIC, Spectrometer, Organic compounds

FT-IR Spectrometer

Make Model: 
Thermo Nicolet Avatar 370
Type of measurement/ Analysis Available: 
FT-IR spectra of solid and liquid samples
Application: 
NA
Major Specifications/ Accessories available: 
Range: 4000- 400 cm-1 FT-IR database for identification of unknown compounds HATR Assembly
Type of facility: 
Institute: 
Sophisticated Test and Instrumentation Centre, Kochi
Meta Tagging: 
STIC, Spectrometer

UV-VIS-NIR Spectrophotometer

Make Model: 
Varian Carry 5000
Type of measurement/ Analysis Available: 
Usual analysis in the region. Absorption, transmittance and quantitative analysis
Application: 
NA
Major Specifications/ Accessories available: 
Range: 190-3200 nm
Resolution: 0.05 nm in UV, 0.2 nm in NIR Wavelength Accuracy: + 0.1 nm (UV-Vis) + 0.4 nm (NIR) Wavelength reproducibility: 0.025 nm Internal DRA available
Type of facility: 
Institute: 
Sophisticated Test and Instrumentation Centre, Kochi
Meta Tagging: 
STIC, Spectrophotometer, Wavelength

UV-VIS-NIR Spectrophotometer

Make Model: 
Varian Carry 5000
Type of measurement/ Analysis Available: 
Usual analysis in the region. Absorption, transmittance and quantitative analysis
Application: 
NA
Major Specifications/ Accessories available: 
Range: 190-3200 nm
Resolution: 0.05 nm in UV, 0.2 nm in NIR Wavelength Accuracy: + 0.1 nm (UV-Vis) + 0.4 nm (NIR) Wavelength reproducibility: 0.025 nm Internal DRA available
Type of facility: 
Institute: 
Sophisticated Test and Instrumentation Centre, Kochi
Meta Tagging: 
STIC, Spectrophotometer, Wavelength

Micro Hardness Tester

Make Model: 
Shimadzu HMV 2T
Type of measurement/ Analysis Available: 
Measurement of surface hardness, hardness of coating as well as parent material.
Application: 
NA
Major Specifications/ Accessories available: 
Load range: 20 gms to 2 kg
Knoop and Vicker’s indenter
35 mm camera attachment
Type of facility: 
Institute: 
Sophisticated Instrumentation Centre for Applied Research and Testing - SICART, Vallabh Vidyanagar
Meta Tagging: 
SICART, Surface Hardness, material

UV-VIS-NIR Spectrometer

Make Model: 
Perkin Elmer Lambda 19
Type of measurement/ Analysis Available: 
All types of measurements/studies in the region including Absorbance, Transmission and Reflectance spectra; Quantitative analysis.
Application: 
NA
Major Specifications/ Accessories available: 
Range: 180-3200 nm
Diffuse reflectance attachment
Colour matching software
Standards for wavelength and absorption calibration validation traceable to NIST
Type of facility: 
Institute: 
Sophisticated Instrumentation Centre for Applied Research and Testing - SICART, Vallabh Vidyanagar
Meta Tagging: 
SICART, Spectrometer, measurement, transmission

Gel Permeation Chromatography

Make Model: 
Perkin Elmer 200
Type of measurement/ Analysis Available: 
Analysis of molecular weight distribution in polymers, resins, oils, aligomers and organic compounds.
Application: 
NA
Major Specifications/ Accessories available: 
Range: 580-107 mw
PLGEL calibration standard (Polystyrene)
Type of facility: 
Institute: 
Sophisticated Instrumentation Centre for Applied Research and Testing - SICART, Vallabh Vidyanagar
Meta Tagging: 
SICART, Chromatography, molecular weight, polymers, resins, oil

Mercury Porosimeter

Make Model: 
Thermoquest Pascal 440 & 140
Type of measurement/ Analysis Available: 
Analysis including pore size/volume distribution, bulk density and specific surface for porous solids.
Application: 
NA
Major Specifications/ Accessories available: 
Range: 400 Kpa to 400 Mpa
Type of facility: 
Institute: 
Sophisticated Instrumentation Centre for Applied Research and Testing - SICART, Vallabh Vidyanagar
Meta Tagging: 
SICART, Mercury porosimeter, density, volumn

Laser Particle Size Analyzer

Make Model: 
Symantec Helos BF
Type of measurement/ Analysis Available: 
Particle size distributions curve; density distributions etc.
Application: 
NA
Major Specifications/ Accessories available: 
Range: 0.1 to 875 microns
32 element array detector
Accessories for dry powders, pastes, liquids and small sample quantities
Type of facility: 
Institute: 
Sophisticated Instrumentation Centre for Applied Research and Testing - SICART, Vallabh Vidyanagar
Meta Tagging: 
SICART, Laser analyzer, density

Thermal Analyzer (DSC, TGA)

Make Model: 
Perkin Elmer Pyris1 DSC, Pyris1 TGA,
Type of measurement/ Analysis Available: 
All types of thermal analysis studies/testing; Thermodynamics, thermal stability, degradation kinetics and quaring kinetics etc.
Application: 
NA
Major Specifications/ Accessories available: 
Temp. range: TGA: RT to 1000 oC DSC: -50 to 550 oC
Type of facility: 
Institute: 
Sophisticated Instrumentation Centre for Applied Research and Testing - SICART, Vallabh Vidyanagar
Meta Tagging: 
SICART, Thermal Analyzer, Thermodynamics

Pages